NFP-E0716M
7mm Encapsulated Vibration Motor – 24mm Type
Technical information for your next design.
Review the specifications and drawings for the exact configuration. Match the mechanical envelope and operating requirements to your assembly.
- Rated voltage
- 3V DC/ 3.7V DC
- Rated speed
- 14,500RPM or 16,500rpm
01 / TECHNICAL REFERENCE
NFP-E0716M Enclosed Vibration Motor Metal Case
This metal capsule encapsulated vibration motor can be used for vibration alerting.
High efficiency | Low energy consumption | Low noise | Small size | Strong sealing | Fast response | Low starting current | Long lifetime
Electrical & performance data
| Rated Voltage: | 3V DC/ 3.7V DC |
|---|---|
| Start Voltage: | 1.0V max |
| Rated Current: | 300mA max |
| Stall Current: | 850mA max |
| Rated Speed: | 14,500RPM or 16,500rpm |
| Terminal Resistance: | 5.6Ω ± 25% |
| Nominal Amplitude Vibe Force: | 5.10G |
Mechanical & operating data
| Motor Model: | NFP-E0716M |
|---|---|
| Body Diameter: | 7.5mm |
| Body Length: | 24mm ± 0.3mm |
| Motor Diameter: | 7mm |
| Motor Length: | 16.6mm |
| Ecc. Weight Radius: | 2.7mm ± 0.1mm |
| Ecc. Weight Length: | 5.0mm |
| Shaft End Play: | 0.05mm – 0.3mm |
| Wire Gauge: | 30AWG UL1571 |
| Wire Length: | 100mm |
02 / TECHNICAL REFERENCE
Overmoldable Vibration Motors Ouline Drawing
Small powerful motors NFP-E0716M is used in Mi Electric Toothbrush. Vibration makes toothbrushes more efficient to use. Also can be used in other applications. Contact us for a quotation for production quantities, customizations and integration.
NFP-E0716-small-vibration-device-outline-drawing
Open full size ↗
03 / TECHNICAL REFERENCE
Encapsulated Vibration Mass Production
enclosed-vibration-motors-mass-production
Open full size ↗
04 / TECHNICAL REFERENCE
7mm Vibration Motors Applications
small-vibration-motor-NFP-E0716M-used-for-real-time-group-monitor-firehud
Open full size ↗
05 / TECHNICAL REFERENCE
Operating Temperature of a Standard Coreless Vibration Motor
The operating temperature of a coreless motor (ironless motor) depends on several factors, including the type of internal magnetic material, winding material, load conditions, and operating environment.
General Operating Temperature Range:
– Recommended Operating Temperature:
-10°C to 60°C
– Maximum Operating Temperature:
-20°C to 80°C
(performance may be affected)
Impact of Temperature on Magnets:
Most
coreless motors use
neodymium (NdFeB) magnets
,
whose magnetic properties weaken as temperature increases,
affecting motor efficiency and output performance:
–
Below 60°C:
Minimal impact, magnetic
properties remain stable.
–
Above 80°C:
Magnetic strength starts to
weaken, reducing motor torque.
–
Above 150°C:
Standard neodymium magnets may
suffer irreversible demagnetization, leading to performance
degradation or motor failure.
How to Prevent High-Temperature Issues:
1.
Reduce Continuous Load
– Avoid running the
motor at full load for long periods to prevent overheating.
2.
Optimize Heat Dissipation
– Ensure proper
ventilation or use heat sinks to maintain a stable operating
temperature.
3.
Use High-Temperature Magnets
– For
applications requiring higher temperatures, consider Samarium
Cobalt (SmCo) magnets, which can withstand up to 250°C.
4.
Adjust Driving Voltage
– Avoid excessive
voltage, which can overheat the windings and shorten motor
lifespan.
If your application requires extended operation in high-temperature environments , it is recommended to consider above points to ensure stability and longevity.
ENGINEERING ENQUIRY
Discuss NFP-E0716M.
Send the model reference, available space, electrical requirements, operating conditions and expected quantity.